Eurocert
CE Marking and Product Certification

ATEX certification: conformity for equipment in explosive atmospheres

Engineer checking Ex-marked equipment in a hazardous-area industrial plant with ATEX zone signage

The order that confuses most first-time applicants

A pump manufacturer in Izmir wins a contract to supply a fuel-transfer skid for a refinery. The purchase order carries one line that stops the project cold: every item entering the process area must be ATEX certified for the relevant zone. The engineering team knows its pumps inside out, yet nobody can say which category the equipment needs, whether a Notified Body has to be involved, or what the marking on the nameplate should read. That gap, between a capable maker and a hazardous-area requirement, is where most ATEX questions begin.

ATEX takes its name from the French phrase "atmospheres explosibles". It governs equipment and protective systems intended for places where flammable gases, vapours, mists or combustible dust can form an explosive atmosphere: refineries, paint shops, flour mills, grain silos, sugar plants, fuel terminals and many chemical sites. This guide stays in the territory that equipment makers and plant engineers actually wrestle with, namely how zones, equipment groups and categories fit together, and the point at which a Notified Body stops being optional.

Two directives that people keep mixing up

Before any certificate, separate the two legal instruments that share the ATEX label. Directive 2014/34/EU is the product directive. It applies to the manufacturer who designs and places equipment on the market, and it is the one that leads to an EU Declaration of Conformity and CE marking. Directive 1999/92/EC is the workplace directive. It applies to the employer who runs the site and has to classify areas into zones, control ignition sources and protect workers.

The split matters because each side leans on the other. The site operator classifies the zones, and the equipment maker then has to supply gear rated for those zones. Get that conversation right early and the specification almost writes itself. Skip it, and you end up with a certified product rated for the wrong zone, which is worse than no certificate at all.

Zones describe the danger, categories describe the equipment

Two scales meet in every ATEX decision, and it pays to hold both in a single view. A zone, assigned by the plant operator under the workplace directive, grades how often an explosive atmosphere is present: Zone 0, 1 and 2 for gases and vapours and Zone 20, 21 and 22 for combustible dust, running from continuous presence down to brief and unlikely. Equipment sits on a parallel scale set by Directive 2014/34/EU: Group I for mining exposed to firedamp and coal dust, Group II for everything else above ground, with Group II split into Categories 1, 2 and 3 and Group I into M1 and M2. A category is really just a promise of how much protection the equipment holds, and how many faults it can survive, while staying safe.

The decision that actually matters is not what each label means on its own, but how you line the two scales up. A higher category buys a higher protection level, and that is what clears equipment for a more dangerous zone, so the specification has to run zone first and category second: read the area's zone off the operator's hazardous-area drawing, then pick equipment whose category is rated for it, never the reverse. Gear rated for a more demanding zone can always drop into a less demanding one, which gives you useful design margin, while the opposite is a non-starter and one of the most common reasons equipment is turned away on site.

Two traps catch teams at exactly this point. Dust zones are the ones most often under-specified, because dust feels tamer than gas when in truth a settled layer both raises the ignition risk and insulates hot surfaces, and its temperature limit is read as an actual maximum surface temperature rather than a class. The other is leaving the zone-to-category match until a supplier has already been chosen. Pinning that mapping down first, agreed in writing with the site operator, is the single habit that separates a project that runs once from one that gets reworked.

ATEX certification: conformity for equipment in explosive atmospheres figure

When a Notified Body is actually mandatory

This is the question that quietly sets cost and lead time, and the answer turns on category, not on how complex the product looks. The higher the category, the more independent oversight the directive pulls into the project, and the earlier that oversight has to land on your schedule.

For the most demanding tier, Category 1 equipment bound for Zone 0 or Zone 20, an external assessment body sits in the loop from the design stage through the production phase. The practical effect on a project is the one to plan for: the design has to be frozen early, third-party assessment becomes a booked milestone you build the timeline around, and the budget has to carry that external involvement from the outset rather than meet it as a late surprise. Group I, Category M1 equipment, which has to keep running even with an explosive atmosphere around it, carries the same weight.

Category 2 equipment for Zone 1 or Zone 21 splits your planning in two, and which side you are on decides how much external time to build in. Electrical equipment and combustion engines draw a third party onto the critical path, so treat that assessment as a fixed date. Other Category 2 equipment, typically mechanical, keeps far more of the work in your own hands but still depends on a documentation step with an external body, which is an administrative slot to schedule rather than a long technical gate. Knowing early which side your product falls on is what lets you size the lead time honestly.

Category 3 equipment for Zone 2 or Zone 22 leaves the schedule almost entirely under your own control, because no external body has to step in. The trade is that the discipline moves inward: the weight shifts onto your own documentation and checks, while the CE marking and the essential safety requirements still apply in full, so a self-assessment never means a lighter product. The planning risk here is not a booking queue but quietly letting internal rigour slip because nobody outside is watching.

A practical sequence keeps the plan honest: settle the zone first, derive the category from it, and let that tell you how much independent involvement and lead time the project really carries, well before you commit a budget. Working the other way around, choosing a route to fit a figure you have already promised, is how equipment ends up under-rated for the area it will actually run in.

Reading the Ex marking string

An ATEX nameplate carries far more than the CE logo and the Ex hexagon. A typical string reads like "II 2 G Ex db IIC T4 Gb", and every block is a decision you can check. "II" is the equipment group, "2" is the category, and "G" says it is for gas, where a "D" would mean dust. After the Ex symbol comes the type of protection, then the gas group, the temperature class and the equipment protection level.

The types of protection are worth knowing by name, because they shape the design. A flameproof enclosure (db) contains an internal explosion and stops it spreading. Increased safety (eb) keeps arcs and hot spots from forming in the first place. Intrinsic safety (ia, ib) limits energy so that no spark can ignite the atmosphere, the usual choice for instrumentation. Pressurisation (px), encapsulation (mb) and non-sparking constructions for Zone 2 round out the options you will see most often.

The temperature class ties the equipment to the chemistry around it. T4 means the maximum surface temperature stays below 135 degrees Celsius, and that figure has to sit under the auto-ignition temperature of the gas present. The gas group, running from IIA up to the harder-to-contain IIC of hydrogen and acetylene, tells you which atmospheres the protection has been proven against. None of this is paperwork for its own sake, it is the language a buyer's safety engineer reads before signing off your equipment.

The non-electrical blind spot

Plenty of manufacturers assume ATEX is only about electrical kit. Mechanical equipment can be an ignition source too, through friction, impact sparks or hot bearing surfaces, so pumps, fans, gearboxes, couplings and conveyors used in a hazardous area fall squarely inside the directive. These items frequently carry obligations under the Machinery Directive at the same time, and the two assessments have to agree on the same residual-risk picture. If you build rotating or moving equipment for industrial sites, treat ATEX and your machinery CE certification as one combined exercise rather than two parallel files.

Where ATEX sits in your wider CE file

ATEX rarely travels alone. A single product can fall under the ATEX directive, the Machinery Directive, the EMC rules and, for some equipment, pressure legislation, yet it ends up with one CE marking supported by one EU Declaration of Conformity that lists every directive applied. Building the file in that joined-up way avoids the classic mistake of certifying against one directive and quietly forgetting another.

For Category 1 and most Category 2 products, the production-phase route leans on a documented quality system covering manufacture, final inspection and testing, the same discipline that underpins ISO 9001 certification. If you are mapping your own route, our pages on ATEX CE marking and the wider CE certificate process set out the assessment options by category, and our specialists can confirm exactly where a Notified Body has to step in for your equipment.